In file 1 and file 2, for matching employeedept only mech, we need to move entire records from file1 to file 2. Do not operate on a file after it is closed with a lock. The open statement was unsuccessful because a conflict was detected between the fixed file attributes and the attributes specified for that. The lightyellow boxes are simotime technologies, thirdparty technologies, decision points or. Provides steps to acquire, install, deploy, and configure your product. Explore how to obtain and display the file status after vsam file status 97. Two interface versions to the msdrg software are supplied. File name in program name had a file specified in the assign clause had a record length of 1600.
The file status field always has value 47, which means something like trying to read from a file thats only open for output right. I am getting file status 39 due to file attribute mismatch. I am creating report with different headers in it and has layout for each header line. Fd file2 recording mode is v block contains 0 records label records are standard. Use the sequential for the initial open output then if that works, close the file then open it using the random.
The first character of the file status key is known as status key1 and defines a group or category. Codes beginning with a 1 are considered at end messages, those beginning with a 2 are considered invalid key messages, file status codes beginning with a 3 are considered permanent errors, keys like 4x are logical errors and 9x are implementer defined. Genrate mini pay slip using mainframecobol,jcl,vsam. In cmpr2, the recordsize defined in your vsam files associated with idcams was not required to match your cobol program file definition for successful file open. If statuskey1 is a nine 9 then statuskey2 is implementerdefined. Oct 20, 2016 for example, if you open a file that is neither optional nor available in extend, io, or input mode, you get file status 35 and the open statement fails. The io errors are automatically trapped by the generated cobol program. The following tables contain filestatuskey content that may be set by micro focus cobol input file that is not present. Job has no config file how to debug a idms batch cobol program. File status keys or return codes for mainframe vs cobol ii, ibm cobol. I have mentioned lrecl as 3 in jcl and recfm as fba. In the reported example of an unbuilt associated alternate index the following message will now be issued. While performing open file and file is not present. It is about combining the latest technologies of the software, documentation or learning material for any purpose.
File status code, return codes for data files and vsam. I have file 1 occurs 5 times with employeeid,employeename,employeedept eee and mech. Ca workload automation esp edition new instructorled training now available for ca workload automation restart option for zos schedulers r11. The lightred boxes are unique to the simotime technologies using a linux, unix or windows system and cobol technologies such as micro focus. Open statement failing for vsam files file status 39. This is usually caused by a conflict with recordlength, keylength, keyposition or file organization. Logic error, a program is attempting a file access function in an improper sequence or beyond the capabilities. The cobol program which reads a varable record layout file gave file status code as 004. Cobol disagrees, which is why you got the 39 file status. File manager has been updated in order to issue a more specific informational message for the open condition and continue processing. Open39 for sequential and relative files, the files attributes do not agree with those specified in the program.
Provides an overview of features and basic use of this product. The simplest fileprocessing program in cobol follows this outline. But after specifying the varying clause in file section, it went fine. Vsam is a file storage access method used in mvs, zos and os390 operating systems.
Explore the nonrelational data connection for more examples of accessing very much. Open 37 for sequential and relative files, the specified open mode is not supported by this file open 38 for sequential and relative files, the file was previously closed with lock open39 for sequential and relative files, the files attributes do not agree with those specified in the program open41 the file is already open. After homologation and testing, acquisition by the first customer is free of charge, with an annual. For example, if you open a file that is neither optional nor available in extend, io, or input mode, you get file status 35 and the open statement fails.
If the file is optional, the same open statement creates the file and returns file status 05. File status 39 while opening the file ibm mainframe. And how can u get the ksds file records into ur cobol program. What could be happening is that if the file you open is a sequential file, you get a file status of 37. I am receiving file status 39 while file2 variable length is being opened. Use test before and test after in the perform statement while writing dowhile statements. Open 38 for sequential and relative files, the file was previously closed with lock. An open operation has been tried on a file previously closed with a lock. Following are the common file status codes with their description which will help you to resolve the issues. You get this return code if the way a file is defined in the program and the way it is allocated by access method services are.
Heres a program that should read a sequential file, create an indexed file and write another sequential file out of the indexed one. In cmpr2, the recordsize defined in your vsam files associated with idcams was not required to match your cobol program file definition for successful. Sep 30, 2015 open 37 for sequential and relative files, the specified open mode is not supported by this file. A file is a collection of data related to a set of entities and typically exists on a magnetic tape or a disk. More information about idcams define is mentioned in ibm redbook vsam demystified section 1. Assuming this is a file status 39, the meaning from the cobol language reference manual is. There was an unsuccessful open or close of file name in program name at relative location x17ee. The lightgreen boxes are unique to simotime technologies using an ibm mainframe system or micro focus enterprise developer. Cannot open a file because of a mismatch of file properties.
I have file 2 occurs 10 times with employeeid,employeename,employeedept eee,civil,chemical and mech. The file status 39 means that there is a difference between what you. The first character of the filestatuskey is known as statuskey1 and defines a group or category. This edition applies to version 4 release 2 of ibm enterprise cobol for zos program number 5655s71 and to all subsequent releases and modifications until otherwise indicated in new editions. If status key1 is a nine 9 then status key2 is implementerdefined. Open statement failing for vsam files file status 39 ibm. An open operation works successfully only when you. A program is a set of instructions that enables a computer to process data, there are two types of computer programs which are 1 operating system programs, which control the overall operation of the system and 2 applications programs, it is the actuall program tasks requried by the users. Vsam is used by cobol and cics in mainframes to store and retrieve data. File status 39 cobol file status code lookup and help. Open failed because of conflicting file attributes. While working with vsam datasets you may encounter abends. Extending the standard browse, edit, copy and print utilities of ispf, file manager delivers functionality that. The ans85 standard provides for a twobyte file status key.
Medicare severity diagnosis related groups msdrg software software installation guide for zos batch vii preface this manual contains the information needed to use the medicare severity diagnosis related groups msdrg software the grouper, version 34. The ans85 standard provides for a twobyte filestatuskey. Running a mainframe cobol code with static file assignments. Introducing rumba provides an introduction to rumba and describes the features provided with rumba. Open statement failing for vsam files file status 39 there is a difference in the way cmpr2 and nocmpr2 handle recordsize defined in vsam files associated with idcams. In your program, organization is relative means the input file must be a relative record data set rrds vsam file, which can be defined using the idcams define command. It is a high performance access method used to organize data in form of files in mainframes. User abend code identifier number in the cobol program filestatus code as per cobol status codes. The system administrator guide contains the following sections. The file property specified in a parameter or option must match with that of the physical file.
The fjsysabe provides the most comprehensive description of the problem. Messages are printed to the system log, fjsyabe and sysout. Neither file status nor an error declarative were specified. A conflict has been detected between the fixed file attributes and the attributes specified for the file in the program. The second character is known as status key2 additional detail. Once the file status is specified within the select statement it is necessary to define the file status field in working storage. Cobol file status 37 when opening sequential dataset with. The lightyellow boxes are simotime technologies, thirdparty technologies, decision points or program. File status code, return codes for data files and vsam simotime. The second character is known as statuskey2 additional detail. How to get the last record in vsam file in cluster.
File status codes beginning with a 0 are considered successful execution. This document and the links to other documents are intended to vsam file status 37 mainframe express or net express or an ibm mainframe system mvs, os390 or. Im new to coding on unix but have coded with cobol on mainframe for a number of years. The following tables contain file status key content that may be set by micro focus cobol input file that is not present. And you did not post key data the 01 definition for the file under fd outputvsam file. The following sections contain the rmcobol file status codes and the. Running a mainframe cobol code with static file assignments under linux environment forum. Learn to activate ca 1 and daily batch processing, maintain the tape library, use auxiliary disposition, and more.
When i execute a cobol load module, i get the following error. What is difference bw file aid tool and file aid utility. This appendix provides guidelines to help prevent common file status 39 problems for qsam files, which are due to mismatches in the attributes. File xxxxfile in program xxxxx01 had a record length of 361 and the file specified in the assign clause had a record length of 360. Mainframe file transfer describes the mainframe file transfer program. Fmnba394 open warning code x64alternate index not built. The referenced optional file is not present at the time the open statement is executed. Display file status information, a suite of cobol programs.
969 1134 791 845 495 928 924 1432 1265 1218 372 1311 76 16 177 922 659 1002 444 498 1414 1216 1376 1542 1322 16 180 319 615 1217 1132 11 275 610 153 944 14 1186 710 449 1344 327 298 590 260